Tilting Disc Check - Installation and Maintenance

General

The tilting disc check valve is designed for installation between two pipe flanges in horizontal pipelines with upward flow.

Installation

To obtain optimum function of the tilting disc check valve and of the circuit in which it is installed, the following instructions should be carefully followed. Consult if in doubt as to the location or function of the tilting disc check valve.

Clamp the valve between the two pipe flanges using through-bolts. Tilting disc check valves are available for all common international flange standards: see catalogue sheet below.

A flow-direction arrow is cast into the check valve body-lifting eye. Make certain that the medium's flow coincides with this arrow.

Centre the tilting disc check valve carefully between the pipe flanges so that the disc can move freely (Fig 1) and is not obstructed by the edge of the pipe flange during operation (Fig 2).

Flange Gaskets

The valve has plane gasket faces. We recommend the following gasket widths for pressure class PN 25 (ANSI 150).

DN
40-150
200-300
350-500
600-1200
Gasket width mm
1.0
1.5
1.8
2.5

PN40/100 (ANSI 300) valve's sealing surfaces are dimensioned for standard gaskets.

Centering

Insert the two bottom through-bolts in the pipe flanges and cradle the tilting disc check valve on these two bolts. Use correctly dimensioned shims to centre the valve. The centring operation may be aided by easing the valve into place with help of wedges hammered between the valve body and the through-bolts.

Make certain that the disc's stub shafts are perfectly horizontal in the horizontal lines. The tilting disc check valve is correctly positioned when the lifting eye on top of the valve body is vertical.

Valves installed in vertical lines must, of course, also be accurately centred. In all conventional applications, the tilting disc check valve must open upwards.

Maintenance

Tilting disc check valves will normally not require any service work. The valve is available with an auxiliary spring to accelerate closing, or without a spring assembly. The springed version is recommended for fluid media. A springless version may easily be equipped with a spring to obtain extra rapid closing.

Valve Flange Index

Valve Flange Index Chart


Product Range
 
Registered Office:
The Farm House, Vantage Business Park,
Bloxham Road, Banbury, Oxfordshire, OX16 9UX

Registered in England No. ­02091066
VAT Registration No. GB ­459 9212 13
Copyright © 2009-2017 Northvale Korting Ltd.
All Rights Reserved.       Website by Metropolis2